Power substation
Application · Power & Energy

Grounding, lightning protection, and substation cable

Utility and substation contractors specify CCS 21% and 30% for grounding grids where copper theft, tensile strength, and long-term corrosion resistance are all critical.

What it is A CCS grounding conductor is a copper-clad steel wire specified for substation ground grids,…
A CCS grounding conductor is a copper-clad steel wire specified for substation ground grids, lightning protection and overhead ground wire where copper theft, tensile loads and long-term corrosion resistance rule out solid copper. RAS Thermal CCS 21% and 30% grades are sized against IEEE 80 fault-current fusing tables, ship with IEC 62561-2 test reports issued per shipment, and deliver 40+ years of service in properly designed grounding grids. In a 500 kV substation retrofit, total installed cost dropped 34% and copper theft incidents fell to zero in the first 18 months.

Installed Cost

34% lower in a 500 kV retrofit

Service Life

40+ years in wet soil

Theft Incidents

Zero in first 18 months

Quote Response

Within 24 hours

How It Works

From spec sheet to production release

01

Design review

IEEE 80 fault-current sizing check with our engineering team.

02

Sample & bend test

Verify installation feasibility on your bending equipment.

03

Certified delivery

IEC 62561-2 test reports issued per shipment.

Key Benefits

Benefit

Theft-deterrent

Low copper content per meter reduces scrap value.

Benefit

IEEE 80 compliant

Sized for typical 1-second fault currents.

Benefit

40-year service life

Verified corrosion performance in wet soil.

Benefit

High tensile

Steel core resists installation and settlement stress.

Selection Guide

The table below compares the conductor options most often specified for power & energy duty, follow the links for full datasheets.

GradeConductivityTypical power & energy use
CCS 21%21% IACSOverhead ground wire, lightning arrest
CCS 30%30% IACSSubstation grounding grids, IEEE 80 sizing
Stranded CCS7/19/37 strandGround braid & messenger, ASTM B229

Frequently Asked Questions (FAQ)

Does CCS meet IEEE 80 fusing? +
Yes, RAS Thermal publishes fusing tables for CCS 21% and 30% at standard fault durations. Contact us for the current revision.
What is the expected service life? +
In properly designed grounding grids, CCS conductors deliver 40+ years of service, comparable to solid copper in most soil chemistries.
Can CCS ground conductors be installed with standard bending equipment? +
Yes, verify bend radius on your existing equipment first, we ship sample lengths for bend testing before volume release. IEC 62561-2 test reports are issued per shipment.
How does CCS reduce total installed cost on a grounding grid? +
Lower copper content per meter cuts conductor cost by 30%+ versus solid copper and reduces scrap-theft losses. In a 500 kV substation retrofit, total installed cost dropped 34% with zero theft incidents in the first 18 months.

Ready to spec RAS Thermal for power & energy?

Standards &. References

IEEE, Institute of Electrical and Electronics Engineers · IEC 62561-2 Lightning Protection